Who gets the mails, and the sender — Settings → App settings
Reload — the board follows what happens by itself
The furnaces and their heats — start the next planning, charge it (by hand or with the crane), add the alloys (the bins), complete the heat
Changes show as they happen — a live connection to the server
Hide the side panel (crane feed, bins) — the furnaces get the width
A bin is being weighed
From above (2D)
In 3D — drag to turn and tilt
Furnace A is selected for EOT Crane 3 T & the bins.
Click to show its card.
Open the Planning screen
The loads EOT Crane 3 T carries into the furnaces' section go onto this furnace's charge mix; the bins pick for this furnace's heat while Pick alloys is ticked (the Bins tab).
Untick to unselect it.
Furnace lining — 68 of 120 heats, 52 left
Melting Bay 1's charge list no. — the last one issued; each heat's first charge takes the next
Ladle lining · Melting Bay 1 — 34 of 150 heats, 116 left
The charge mix was closed 3:16 AM by Vignesh P — the alloys are added from the bins
Lab result 31 Oct, 03:30 · tested by R.B
Carbon Raiser
Ferro Silicon
Ferro Manganese
Phosphorus
Sulphur
Copper
Magnesium
Not in the aim — shown for its lab % (Masters → Elements: Show in lab results); nothing is required of it
Aim 3.65 % · band 3.6 – 3.75
Base Si aim 2.217 % — the treatment adds the rest (aim 2.45 %)
Aim 0.32 % · band 0.27 – 0.4
Aim 0.035 % · band 0 – 0.06
Aim 0.012 % · band 0 – 0.02
Aim 0.45 % · band 0.4 – 0.5
Aim 0.045 % · band 0.035 – 0.06
(3.65 − 3.526) × 1000 kg ÷ 90 % = 1.38 kg
(2.217 − 1.976) × 1000 kg ÷ 70 % = 3.44 kg
At or above the target — nothing to add
No pickup % — set it in the charge mix
What the bins' weigh-ups took against the I-Initial result
B2 · 3:36:00 AM by Vignesh P · picked — recorded by itself: the bin 36.17 → 34.473 kg
Undo — recorded by mistake
B1 · 3:35:44 AM by Vignesh P · picked — recorded by itself: the bin 18.282 → 16.895 kg
B4 · 3:17:20 AM by Vignesh P · picked — recorded by itself: the bin 10.497 → 7.398 kg
B2 · 3:17:04 AM by Vignesh P · picked — recorded by itself: the bin 45.871 → 36.17 kg
B1 · 3:16:48 AM by Vignesh P · picked — recorded by itself: the bin 23.581 → 18.282 kg
Back to charging: the crane and the charge mix may change it again
Enter the melt lab's readings, the temperatures, the tapping and pouring — optional
The raw materials on the charge against the charging weight
Closed 3:16 AM by Vignesh P — the alloys are added from the bins; the crane no longer charges it
Each raw material against the fewest additions suggestion (made 2:26 am by Vignesh P): Target is its kg, Actual what is on the charge — the crane's loads and any kg by hand.
Not suggested — on the charge, though the suggestion leaves it out.
Hourglass — suggested, not loaded yet; a warning once the charge is through without it.
Scheduled 30 Oct 2026, 1:06 PM by Karthik Raman
On furnace 31 Oct 2026, 2:26 AM by Vignesh P
Charged 31 Oct 2026, 2:34 AM by Vignesh P — click: view the charge mix
Additions 31 Oct 2026, 3:16 AM by Vignesh P
I-Initial 31 Oct 2026, 3:30 AM · tested by R.B — click: view the lab result
Tick to select Furnace B: the loads EOT Crane 3 T carries into the furnaces' section go onto its charge mix; the bins pick for its heat while Pick alloys is ticked (the Bins tab).
Furnace A is unselected then — one furnace a bay.
Furnace lining — 21 of 120 heats, 99 left
The next heat: it moves onto Furnace B when the heat on it is completed — charged with what was loaded for it.
nothing loaded yet
Tick the furnace on this tab: EOT Crane 3 T's loads go onto it.
Ferro Chrome
Tin
Aim 3.3 % · band 3.25 – 3.4
Aim 2.05 % · band 1.95 – 2.15
Aim 0.7 % · band 0.65 – 0.8
Aim 0.06 % · band 0 – 0.1
Aim 0.06 % · band 0.04 – 0.1
Aim 0.2 % · band 0.17 – 0.25
Aim 0.05 % · band 0.04 – 0.07
The addition to be made: the absolute addition ÷ pickup × 100
Nothing short
The charge mix's Addition — the bins' weigh-ups go onto it
The crane's loads into the furnaces' section go onto this charge mix while Furnace B is selected for the crane
Each raw material against the fewest additions suggestion (made 3:18 am automatically): Target is its kg, Actual what is on the charge — the crane's loads and any kg by hand.
Not suggested — on the charge, though the suggestion leaves it out.
Hourglass — suggested, not loaded yet; a warning once the charge is through without it.
On the charge — the crane's loads, and any kg by hand
The fewest additions suggestion's kg of it — what the crane is to load
Filled by the crane
Crane load from B01 · 3:25:52 AM
Crane load from B02 · 3:29:44 AM
Crane load from B05 · 3:33:20 AM
The fewest additions suggestion (the drawing's charge rules) — made 3:18 AM automatically
On furnace 31 Oct 2026, 3:18 AM
Charged 31 Oct 2026, 3:25 AM by the crane — click: view the charge mix
The lab's first result, expected after the additions
Tick to select Furnace C: the loads EOT Crane 3 T carries into the furnaces' section go onto its charge mix; the bins pick for its heat while Pick alloys is ticked (the Bins tab).
Furnace A is unselected then — one furnace a bay.
Furnace lining — 101 of 110 heats, 9 left
Issued with the first charge mix
Put the planning back in the queue — nothing has been charged or numbered yet
The crane's loads into the furnaces' section go onto this charge mix while Furnace C is selected for the crane
Each raw material against the fewest additions suggestion (made 3:45 am automatically): Target is its kg, Actual what is on the charge — the crane's loads and any kg by hand.
Not suggested — on the charge, though the suggestion leaves it out.
Hourglass — suggested, not loaded yet; a warning once the charge is through without it.
Suggested — not loaded yet
The fewest additions suggestion (the drawing's charge rules) — made 3:45 AM automatically
On furnace 31 Oct 2026, 3:16 AM by Vignesh P
A weigh-up is taken against the lab's latest result
Closed 3:16 AM by Vignesh P — its alloys come from the bins: no crane loads, no charge-mix changes till it is unlocked
Pick alloys is on for this heat — untick it first, then unlock the charge mix
Melting Bay 1's bins' feed — its PLC topic (bin/data) — sent nothing for 15 minutes or more: the scales weigh nothing meanwhile.
The Addition locked to the bins (Settings → App settings) is typed on the charge mix till a message comes again — then it is locked again (what was typed meanwhile stays on the heat).
Every pick from Melting Bay 1's bins goes onto heat 24654 — each bin's scale fall, as its element (before the lab onto the charge mix's addition, after a lab result against it).
Untick when the picking for it is done.
Pick alloys is on — what is picked from it goes onto the heat by itself
Picked from: what the bin loses since it was ticked is added
Pick alloys ticked 3:35:28 AM by Vignesh P for heat 24654
Type a pick its scale did not see (silent or wrong) — what it sees is recorded by itself
What is picked from B1 goes onto heat 24654 as C by itself — no need to tick it
Last: 1.387 kg (the bin 18.282 → 16.895 kg) · Vignesh P
A pick its scale did not see (silent or wrong): ✎ type it
Its element's stock (Stock → Elements)
What is picked from B3 goes onto heat 24654 as Mn by itself — no need to tick it
A pick its scale did not see (silent or wrong): ✎ type it
What is picked from B4 goes onto heat 24654 as Cu by itself — no need to tick it
Last: 3.099 kg (the bin 10.497 → 7.398 kg) · Vignesh P
A pick its scale did not see (silent or wrong): ✎ type it
What is picked from B5 goes onto heat 24654 as Cr by itself — no need to tick it
A pick its scale did not see (silent or wrong): ✎ type it
B6: Sn is not a chemistry column of heat 24654 — its iron type does not add it
Pick the element to weigh in B9
Kilowatt-hour and On Time counting since 3:18 am — 39 min.
When both go back to 0 the melt is over — the heat on it is completed by itself while Settings → App settings lets the panel do it.
Kilowatt-hour and On Time counting since 3:16 am — 41 min.
When both go back to 0 the melt is over — the heat on it is completed by itself while Settings → App settings lets the panel do it.
Kilowatt-hour and On Time counting since 2:26 am — 1 h 31 min.
When both go back to 0 the melt is over — the heat on it is completed by itself while Settings → App settings lets the panel do it.
The furnace's panel, read over Modbus (Settings → Modbus).
The last reading 3:57:34 am.