Lab result · I-Initial · Heat 24653
Furnace B · 31 Oct 2026, 2:15 AM · tested by R.B
View only
Drawing
NA-7731-BH Bearing Housing · Nila Auto Components
Grade (the lab's)
FG260
Charging WT
1,000 kg
C pickup after spectrum
90 %
Result
the 1st of 3
Per element8
ElementTarget %Lab %Pickup %Required kgTaken kgLeft kg
C3.3 3.307 in band90 — — —
Si2.05 1.769 low70 4.01 ₹506.26 3.997 ₹504.620.013
Mn0.7 0.565 low68 1.99 ₹195.36 2.149 ₹210.97—
P0.06 0.0508 low— — — —
S0.06 0.0416 low— — — —
Cr0.2 0.212 in band62 — — —
Cu0.45 0.463 in band95 — — —
Sn0.05 0.0461 low90 0.04 ₹106.90 — 0.04
Cost of the additions₹808.52₹715.59

Required = (target − lab %) × charging weight ÷ pickup %, while the lab % is under the target (C: the carbon pickup after spectrum). Taken: the bins' weigh-ups against this result. ₹ at each element's rate on the heat's charge mix.

Also reported6
Mg0.0027Ni0.0418Mo0.0053Ti0.0232Al0.0139Fe93.459
The board's message$H:24653,G:FG260,T:R.B,ST:BI-Initial,C:3.307,Si:1.769,Mn:0.565,P:0.0508,S:0.0416,Cr:0.212,Cu:0.463,Mg:0.0027,Sn:0.0461,Ni:0.0418,Mo:0.0053,Ti:0.0232,Al:0.0139,Fe:93.459,fur:2#