Suggestion Dashboard
Month
All furnaces
Suggestion used
51.8 %
of the heats charged by hand
Kept as suggested
62.3 %
of the times it was used
Met at the first initial
92.9 %vs73.8 %
as suggested · by hand
Suggestion picked
91fewest additions36lowest cost
As suggested 127Changed after using 77Typed by hand 190Crane 105
What the heats came to averages a heat · the best of the hand-charged kinds marked
| As suggested | Changed after using | Typed by hand | Crane | |
|---|---|---|---|---|
| Heats | 127 | 77 | 190 | 105 |
| Off the suggestion | 0 % | 10.1 % | 26.2 % | 1.8 % |
| Additions the charge left | 19.87 kg | 20.35 kg | 25.98 kg | 18.24 kg |
| Added on the charge mix | 20.47 kg | 21.48 kg | 27.41 kg | 18.46 kg |
| Met at the first initial | 92.9 % | 79.2 % | 71.6 % | 84.6 % |
| Asked for at the first initial | 0.45 kg | 0.68 kg | 0.87 kg | 0.51 kg |
| Corrections after the lab | 0.07 kg | 0.02 kg | 0.05 kg | 0 kg |
| Needed a second initial | 6.3 % | 20.8 % | 28.4 % | 15.4 % |
| Charge mix | ₹36,898 | ₹38,132 | ₹37,370 | ₹36,992 |
| Alloys | ₹3,718 | ₹3,938 | ₹4,437 | ₹3,340 |
| Total | ₹40,616 | ₹42,070 | ₹41,807 | ₹40,332 |
| Charge → first initial | 47 min | 48 min | 47 min | 47 min |
| Charge → completed | 94 min | 97 min | 95 min | 95 min |
Over time heats a day
By user who saved the charge mix
| User | Heats | How | Used |
|---|---|---|---|
| Senthil Kumar | 249 | 55 % | |
| Murugan S | 156 | 51 % | |
| Vignesh P | 82 | 44 % | |
| the crane | 12 | — |
The latest heats 100 of 499
| Charged | Heat no. | Furnace | Drawing | Charge mix | Suggestion | Off it % | Additions kg | First initial | Saved by |
|---|---|---|---|---|---|---|---|---|---|
| 31 Oct, 3:25 AM | 24655 | Furnace B | NA-7731-BH · Bearing Housing | Crane | — | 22 | 41.02 | — | the crane |
| 31 Oct, 2:34 AM | 24654 | Furnace A | AH-1042-PC · Pump Casing | As suggested | Fewest additions | 0 | 17.36 | 4.82 kg | Vignesh P |
| 31 Oct, 1:29 AM | 24653 | Furnace B | NA-7731-BH · Bearing Housing | Typed by hand | — | 15 | 28.05 | 6.04 kg | Vignesh P |
| 31 Oct, 1:19 AM | 24652 | Furnace C | AH-1187-GC · Gear Box Cover | Crane | — | 2.7 | 14.11 | met | the crane |
| 31 Oct, 12:29 AM | 24651 | Furnace A | AH-1042-PC · Pump Casing | Typed by hand | — | 20.5 | 25.28 | met | Vignesh P |
| 30 Oct, 11:50 PM | 24650 | Furnace B | NA-7731-BH · Bearing Housing | As suggested | Fewest additions | 0 | 22.54 | met | Vignesh P |
| 30 Oct, 11:15 PM | 24649 | Furnace C | AH-1187-GC · Gear Box Cover | Crane | — | 2.7 | 14.01 | met | the crane |
| 30 Oct, 10:29 PM | 24648 | Furnace A | AH-1042-PC · Pump Casing | Crane | — | 1 | 16.85 | met | Vignesh P |
| 30 Oct, 10:10 PM | 24647 | Furnace B | NA-7731-BH · Bearing Housing | As suggested | Fewest additions | 0 | 22.54 | met | Vignesh P |
| 30 Oct, 9:20 PM | 24646 | Furnace C | AH-1187-GC · Gear Box Cover | Crane | — | 0.7 | 13.47 | met | the crane |
| 30 Oct, 8:31 PM | 24645 | Furnace A | AH-1042-PC · Pump Casing | Typed by hand | — | 29.5 | 28.3 | met | Vignesh P |
| 30 Oct, 8:25 PM | 24644 | Furnace B | NA-7731-BH · Bearing Housing | Typed by hand | — | 25 | 31.2 | 1.26 kg | Vignesh P |
| 30 Oct, 7:18 PM | 24643 | Furnace C | AH-1187-GC · Gear Box Cover | Typed by hand | — | 26.7 | 19.65 | met | Senthil Kumar |
| 30 Oct, 6:40 PM | 24642 | Furnace B | AH-1042-PC · Pump Casing | Crane | — | 1.5 | 17.55 | met | Vignesh P |
| 30 Oct, 6:30 PM | 24641 | Furnace A | AH-1187-GC · Gear Box Cover | Crane | — | 1.5 | 18.43 | met | the crane |
| 30 Oct, 5:23 PM | 24640 | Furnace C | AH-1187-GC · Gear Box Cover | Crane | — | 0.7 | 13.56 | met | the crane |
| 30 Oct, 4:36 PM | 24639 | Furnace B | AH-1042-PC · Pump Casing | Typed by hand | — | 30.5 | 29.24 | 1.84 kg | Senthil Kumar |
| 30 Oct, 4:25 PM | 24638 | Furnace A | AH-1187-GC · Gear Box Cover | Typed by hand | — | 35 | 28.86 | met | Senthil Kumar |
| 30 Oct, 3:19 PM | 24637 | Furnace C | AH-1187-GC · Gear Box Cover | Crane | — | 2 | 12.98 | met | the crane |
| 30 Oct, 2:32 PM | 24636 | Furnace B | AH-1042-PC · Pump Casing | As suggested | Lowest cost | 0 | 23.67 | met | Senthil Kumar |
| 30 Oct, 2:19 PM | 24635 | Furnace A | AH-1187-GC · Gear Box Cover | Crane | — | 1.5 | 16.35 | met | the crane |
| 30 Oct, 1:24 PM | 24634 | Furnace C | AH-1187-GC · Gear Box Cover | Crane | — | 2 | 14.31 | met | the crane |
| 30 Oct, 12:26 PM | 24633 | Furnace B | AH-1042-PC · Pump Casing | Typed by hand | — | 24.5 | 26.83 | met | Murugan S |
| 30 Oct, 12:18 PM | 24632 | Furnace A | NA-7731-BH · Bearing Housing | As suggested | Fewest additions | 0 | 22.54 | met | Senthil Kumar |
| 30 Oct, 11:46 AM | 24631 | Furnace C | AH-1187-GC · Gear Box Cover | Typed by hand | — | 26.7 | 19.65 | met | Senthil Kumar |
| 30 Oct, 10:22 AM | 24630 | Furnace B | KP-2210-IMP · Impeller | As suggested | Fewest additions | 0 | 16.1 | met | Senthil Kumar |
| 30 Oct, 10:21 AM | 24629 | Furnace A | NA-7731-BH · Bearing Housing | Changed after using | Fewest additions | 10 | 23.32 | met | Senthil Kumar |
| 30 Oct, 10:13 AM | 24628 | Furnace C | AH-1187-GC · Gear Box Cover | As suggested | Fewest additions | 0 | 13.14 | met | Murugan S |
| 30 Oct, 8:31 AM | 24627 | Furnace C | AH-1187-GC · Gear Box Cover | Crane | — | 2.7 | 14.65 | met | the crane |
| 30 Oct, 8:29 AM | 24626 | Furnace B | KP-2210-IMP · Impeller | Crane | — | 1.5 | 17.17 | met | Murugan S |
| 30 Oct, 8:05 AM | 24625 | Furnace A | NA-7731-BH · Bearing Housing | Typed by hand | — | 25 | 31.2 | met | Senthil Kumar |
| 30 Oct, 6:48 AM | 24624 | Furnace C | AH-1187-GC · Gear Box Cover | As suggested | Fewest additions | 0 | 13.14 | met | Murugan S |
| 30 Oct, 6:37 AM | 24623 | Furnace B | KP-2210-IMP · Impeller | Typed by hand | — | 14.5 | 20.84 | met | Senthil Kumar |
| 30 Oct, 6:18 AM | 24622 | Furnace A | NA-7731-BH · Bearing Housing | Changed after using | Fewest additions | 10 | 21.73 | 1.52 kg | Senthil Kumar |
| 29 Oct, 8:10 PM | 24621 | Furnace B | VC-3305-VB · Valve Body | As suggested | Lowest cost | 0 | 27.82 | met | Senthil Kumar |
| 29 Oct, 6:09 PM | 24620 | Furnace B | VC-3305-VB · Valve Body | Typed by hand | — | 39.5 | 28.63 | met | Vignesh P |
| 29 Oct, 6:05 PM | 24619 | Furnace A | AH-1042-PC · Pump Casing | Changed after using | Fewest additions | 5 | 21.2 | met | Vignesh P |
| 29 Oct, 4:06 PM | 24618 | Furnace B | AH-1042-PC · Pump Casing | Crane | — | 0.5 | 19.69 | met | Vignesh P |
| 29 Oct, 4:05 PM | 24617 | Furnace A | VC-3305-VB · Valve Body | As suggested | Fewest additions | 0 | 18.58 | met | Vignesh P |
| 29 Oct, 2:12 PM | 24616 | Furnace B | AH-1042-PC · Pump Casing | Changed after using | Fewest additions | 10 | 23.03 | met | Vignesh P |
| 29 Oct, 2:05 PM | 24615 | Furnace A | VC-3305-VB · Valve Body | As suggested | Fewest additions | 0 | 18.58 | met | Murugan S |
| 29 Oct, 12:13 PM | 24614 | Furnace B | AH-1042-PC · Pump Casing | As suggested | Fewest additions | 0 | 19.37 | met | Senthil Kumar |
| 29 Oct, 12:03 PM | 24613 | Furnace A | KP-2210-IMP · Impeller | As suggested | Lowest cost | 0 | 22.41 | met | Murugan S |
| 29 Oct, 11:50 AM | 24612 | Furnace C | NA-7731-BH · Bearing Housing | As suggested | Lowest cost | 0 | 20.35 | 3.26 kg | Senthil Kumar |
| 29 Oct, 10:26 AM | 24611 | Furnace B | AH-1042-PC · Pump Casing | As suggested | Lowest cost | 0 | 25.67 | met | Murugan S |
| 29 Oct, 10:20 AM | 24610 | Furnace C | NA-7731-BH · Bearing Housing | Typed by hand | — | 13.3 | 20.94 | met | Murugan S |
| 29 Oct, 10:02 AM | 24609 | Furnace A | KP-2210-IMP · Impeller | As suggested | Fewest additions | 0 | 16.1 | met | Murugan S |
| 29 Oct, 8:37 AM | 24608 | Furnace B | KP-2210-IMP · Impeller | As suggested | Lowest cost | 0 | 22.41 | met | Murugan S |
| 29 Oct, 8:32 AM | 24607 | Furnace C | NA-7731-BH · Bearing Housing | Crane | — | 3.3 | 18.87 | met | the crane |
| 29 Oct, 8:13 AM | 24606 | Furnace A | KP-2210-IMP · Impeller | Typed by hand | — | 29.5 | 25.95 | met | Murugan S |
| 29 Oct, 6:57 AM | 24605 | Furnace C | NA-7731-BH · Bearing Housing | Crane | — | 2.7 | 18.21 | met | the crane |
| 29 Oct, 6:32 AM | 24604 | Furnace B | KP-2210-IMP · Impeller | Typed by hand | — | 19.5 | 22.57 | met | Murugan S |
| 29 Oct, 6:20 AM | 24603 | Furnace A | KP-2210-IMP · Impeller | As suggested | Fewest additions | 0 | 16.1 | met | Senthil Kumar |
| 28 Oct, 7:53 PM | 24602 | Furnace B | VC-3305-VB · Valve Body | Changed after using | Fewest additions | 15 | 13.36 | met | Senthil Kumar |
| 28 Oct, 6:11 PM | 24601 | Furnace A | AH-1042-PC · Pump Casing | As suggested | Lowest cost | 0 | 25.67 | 2.46 kg | Senthil Kumar |
| 28 Oct, 5:57 PM | 24600 | Furnace B | VC-3305-VB · Valve Body | Changed after using | Fewest additions | 15 | 22.97 | met | Senthil Kumar |
| 28 Oct, 4:22 PM | 24599 | Furnace A | AH-1042-PC · Pump Casing | Typed by hand | — | 29.5 | 30.13 | met | Vignesh P |
| 28 Oct, 3:54 PM | 24598 | Furnace B | VC-3305-VB · Valve Body | Typed by hand | — | 34.5 | 29.16 | met | Vignesh P |
| 28 Oct, 2:14 PM | 24597 | Furnace A | KP-2210-IMP · Impeller | As suggested | Lowest cost | 0 | 22.41 | met | Senthil Kumar |
| 28 Oct, 2:06 PM | 24596 | Furnace B | VC-3305-VB · Valve Body | As suggested | Lowest cost | 0 | 27.82 | met | Senthil Kumar |
| 28 Oct, 12:24 PM | 24595 | Furnace A | KP-2210-IMP · Impeller | Crane | — | 2.5 | 17.65 | met | Murugan S |
| 28 Oct, 12:11 PM | 24594 | Furnace B | AH-1042-PC · Pump Casing | Changed after using | Lowest cost | 10 | 25.19 | met | Murugan S |
| 28 Oct, 11:52 AM | 24593 | Furnace C | VC-3305-VB · Valve Body | As suggested | Fewest additions | 0 | 14.82 | met | Murugan S |
| 28 Oct, 10:25 AM | 24592 | Furnace B | AH-1042-PC · Pump Casing | Typed by hand | — | — | 27.87 | met | Murugan S |
| 28 Oct, 10:12 AM | 24591 | Furnace A | KP-2210-IMP · Impeller | As suggested | Lowest cost | 0 | 23.06 | met | Senthil Kumar |
| 28 Oct, 10:03 AM | 24590 | Furnace C | VC-3305-VB · Valve Body | As suggested | Fewest additions | 0 | 14.38 | met | Senthil Kumar |
| 28 Oct, 8:37 AM | 24589 | Furnace C | VC-3305-VB · Valve Body | Crane | — | 1.5 | 15.28 | met | Senthil Kumar |
| 28 Oct, 8:35 AM | 24588 | Furnace B | AH-1042-PC · Pump Casing | Changed after using | Lowest cost | 10 | 25.76 | met | Murugan S |
| 28 Oct, 8:27 AM | 24587 | Furnace A | KP-2210-IMP · Impeller | As suggested | Lowest cost | 0 | 23.06 | met | Senthil Kumar |
| 28 Oct, 6:56 AM | 24586 | Furnace C | VC-3305-VB · Valve Body | Crane | — | 2.6 | 13.59 | met | Senthil Kumar |
| 28 Oct, 6:38 AM | 24585 | Furnace B | AH-1042-PC · Pump Casing | As suggested | Fewest additions | 0 | 19.98 | met | Senthil Kumar |
| 28 Oct, 6:21 AM | 24584 | Furnace A | KP-2210-IMP · Impeller | Typed by hand | — | 29.5 | 26.86 | 5 kg | Murugan S |
| 27 Oct, 6:24 PM | 24583 | Furnace A | KP-2210-IMP · Impeller | As suggested | Fewest additions | 0 | 16.69 | met | Senthil Kumar |
| 27 Oct, 6:20 PM | 24582 | Furnace B | KP-2210-IMP · Impeller | As suggested | Lowest cost | 0 | 23.06 | met | Senthil Kumar |
| 27 Oct, 4:23 PM | 24581 | Furnace B | KP-2210-IMP · Impeller | Crane | — | 1.5 | 16.71 | met | Senthil Kumar |
| 27 Oct, 4:15 PM | 24580 | Furnace A | KP-2210-IMP · Impeller | Changed after using | Fewest additions | 10 | 13.72 | met | Vignesh P |
| 27 Oct, 2:21 PM | 24579 | Furnace B | VC-3305-VB · Valve Body | As suggested | Lowest cost | 0 | 28.26 | met | Vignesh P |
| 27 Oct, 2:04 PM | 24578 | Furnace A | KP-2210-IMP · Impeller | Typed by hand | — | 19.5 | 23.39 | met | Senthil Kumar |
| 27 Oct, 12:14 PM | 24577 | Furnace B | VC-3305-VB · Valve Body | Changed after using | Fewest additions | 10 | 16.44 | met | Senthil Kumar |
| 27 Oct, 12:11 PM | 24576 | Furnace C | NA-7731-BH · Bearing Housing | Typed by hand | — | 26.7 | 24.26 | met | Senthil Kumar |
| 27 Oct, 11:55 AM | 24575 | Furnace A | KP-2210-IMP · Impeller | Crane | — | 2.5 | 18.07 | met | Murugan S |
| 27 Oct, 10:23 AM | 24574 | Furnace C | NA-7731-BH · Bearing Housing | Typed by hand | — | 20 | 23.03 | met | Murugan S |
| 27 Oct, 10:22 AM | 24573 | Furnace B | VC-3305-VB · Valve Body | Changed after using | Fewest additions | 10 | 22.43 | met | Murugan S |
| 27 Oct, 10:04 AM | 24572 | Furnace A | KP-2210-IMP · Impeller | Typed by hand | — | 24.5 | 25.17 | met | Senthil Kumar |
| 27 Oct, 8:36 AM | 24571 | Furnace C | NA-7731-BH · Bearing Housing | As suggested | Fewest additions | 0 | 17.26 | met | Senthil Kumar |
| 27 Oct, 8:21 AM | 24570 | Furnace B | VC-3305-VB · Valve Body | Crane | — | 3.2 | 20.82 | met | Murugan S |
| 27 Oct, 8:10 AM | 24569 | Furnace A | KP-2210-IMP · Impeller | Typed by hand | — | 29.5 | 26.56 | met | Murugan S |
| 27 Oct, 6:47 AM | 24568 | Furnace C | NA-7731-BH · Bearing Housing | As suggested | Fewest additions | 0 | 17.26 | met | Senthil Kumar |
| 27 Oct, 6:29 AM | 24567 | Furnace B | VC-3305-VB · Valve Body | Typed by hand | — | 38.3 | 31.32 | met | Senthil Kumar |
| 27 Oct, 6:12 AM | 24566 | Furnace A | KP-2210-IMP · Impeller | Crane | — | 2 | 18.05 | met | Senthil Kumar |
| 26 Oct, 6:28 PM | 24565 | Furnace A | VC-3305-VB · Valve Body | Crane | — | 1.5 | 20.57 | met | Senthil Kumar |
| 26 Oct, 6:25 PM | 24564 | Furnace B | AH-1042-PC · Pump Casing | As suggested | Lowest cost | 0 | 26.36 | met | Vignesh P |
| 26 Oct, 4:36 PM | 24563 | Furnace A | AH-1042-PC · Pump Casing | Changed after using | Fewest additions | 10 | 23.55 | 1.68 kg | Senthil Kumar |
| 26 Oct, 4:22 PM | 24562 | Furnace B | KP-2210-IMP · Impeller | Changed after using | Lowest cost | 10 | 26.45 | met | Senthil Kumar |
| 26 Oct, 2:43 PM | 24561 | Furnace A | AH-1042-PC · Pump Casing | Typed by hand | — | 14.5 | 24.49 | 1.09 kg | Senthil Kumar |
| 26 Oct, 2:12 PM | 24560 | Furnace B | KP-2210-IMP · Impeller | Changed after using | Lowest cost | 15 | 28.14 | met | Vignesh P |
| 26 Oct, 12:29 PM | 24559 | Furnace A | AH-1042-PC · Pump Casing | Typed by hand | — | 40.5 | 33.65 | met | Senthil Kumar |
| 26 Oct, 12:05 PM | 24558 | Furnace B | AH-1042-PC · Pump Casing | Typed by hand | — | 29.5 | 29 | met | Senthil Kumar |
| 26 Oct, 11:39 AM | 24557 | Furnace C | NA-7731-BH · Bearing Housing | Typed by hand | — | 26.7 | 24.05 | met | Senthil Kumar |
| 26 Oct, 10:37 AM | 24556 | Furnace A | AH-1042-PC · Pump Casing | Changed after using | Lowest cost | 10 | 27.62 | met | Murugan S |